{"AlternateComparison":false,"RelatedProducts":true,"Specification":true,"FeatureBenefit":false}
Phasix™ Bioresorbable mesh Phasix™ ST Mesh

Phasix™ ST Mesh, Rectangle, 10 cm x 15 cm (4 in x 6 in)

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.800.556.6756
BDISurgery@bd.com
Onsite Visiting
Location Icon
100 Crossings BoulevardWarwick, Rhode Island 02886United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Monday to Friday 8:15 AM to 6:00 PM EST
Fax Icon
1.800.531.4124
Custserv.davol@bd.com
Shipping a Product Back
Location Icon
100 Crossings Boulevard, Warwick, Rhode Island 02886, United States
Overview

Designed for a strong repair enables functional tissue remodeling


Phasix™ ST Mesh combines two market-leading technologies into one product: monofilament resorbable Phasix™ Mesh and a proven hydrogel barrier based on Sepra® technology. While the monofilament mesh supports functional healing and a strong repair, the hydrogel barrier minimizes tissue attachment to the visceral side of the mesh for intraabdominal placement.1

These meshes are available in different shapes, such as round, rectangle, and square.

For high-risk/comorbid patients, surgeons have had to choose between permanent synthetic meshes and biologic grafts—and their inherent pros and cons. Synthetic meshes can have complications that lead to mesh removal or reoperation, while biologic grafts can have accelerated degradation in the presence of bacteria which may lead to mesh failure.

Phasix™ ST Mesh handles, sutures and fixates like a synthetic mesh, while exhibiting the remodeling characteristics of a biologic mesh. It facilitates trocar deployment during laparoscopic placement.

The ST hydrogel barrier

  • Minimizes risk of tissue attachment
  • Has over 10 years of clinical application
  • Resorbs in 30 days
  • 15 clinical studies
     

The Phasix™ ST Mesh is a biologically derived scaffold with a hydrogel barrier for intraabdominal placement. It has been designed to provide the repair strength of a synthetic mesh and the remodeling characteristics of a biologic.

The Phasix™ ST Mesh does the following: 

  • Handles, sutures and fixates like a synthetic mesh
  • Facilitates trocar deployment during laparoscopic placement
  • Its longitudinal stripes aid with orientation and visibility during placement
true
Features and Benefits
Promotional Story
false
References

1. Deeken CR, Matthews BD. “Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-Phasix™ Mesh) in a porcine model of hernia repair.” ISRN Surgery 2013; 1-12. RPT3807332.

2. DeMeester, Steven R, et al. Combination of surgical technique and bioresorbable mesh reinforcement of the crural repair leads to low early hernia recurrence rates with laparoscopic paraesophageal hernia repair. J Gastrointest Surg. 2020

Indications

Phasix™ ST Mesh is indicated for use in the reinforcement of soft tissue, where weakness exists, in procedures involving soft tissue repair, such as for the repair of hernias, including hiatal hernias.

Contraindications

Because Phasix™ ST Mesh is fully resorbable, it should not be used in repairs where permanent wound or organ support from the mesh is required.

Warnings

Device manufacture involves exposure to tetracycline hydrochloride and kanamycin sulfate. The safety and product use for patients with hypersensitivities to these antibiotics is unknown. Use of this device in patients with known allergies to tetracycline hydrochloride or kanamycin sulfate should be avoided.

Ensure proper orientation; the coated side of the prosthesis should be oriented against the bowel or sensitive organs.

Do not place the uncoated mesh side against the bowel. There is a risk for adhesion formation or erosions when the uncoated mesh side is placed in direct contact with the bowel or viscera. (Reference Surface Orientation section.)

The safety and effectiveness of Phasix™ ST Mesh in bridging repairs has not been evaluated or established. The use of any synthetic mesh or patch in a contaminated or infected wound could lead to fistula formation and/or extrusion of the mesh and it is not recommended.

If an infection develops, treat the infection aggressively. Consideration should be given regarding the need to remove the mesh. An unresolved infection may require removal of the mesh.

For hiatal hernia repair, the use of Phasix™ ST Mesh circumferentially around the esophagus is not recommended.

For hiatal hernia repair, the use of Phasix™ ST Mesh to bridge the hiatus is not recommended.

The safety and effectiveness of Phasix™ ST Mesh in the following applications has not been evaluated or established: Pregnant women, Pediatric use, Neural and Cardiovascular tissue.

Precautions

The safety and effectiveness of Phasix™ ST Mesh has not been evaluated in the presence of malignancies in the abdominopelvic cavity.

Adverse Reactions

In preclinical testing, Phasix™ ST Mesh elicited a minimal tissue reaction characteristic of foreign body response to a substance. The tissue reaction resolved as the mesh was resorbed. Possible complications may include, but are not limited to, seroma, adhesion, hematoma, pain, infection, inflammation, allergic reaction, hemorrhage, extrusion, erosion, migration, fistula formation, and recurrence of the hernia or soft tissue defect. Possible complications in hiatal hernia repair may include esophageal erosion and dysphagia related to crural fibrosis.

Please consult package insert for more detailed safety information and instructions for use.

true
Specification

GTIN - Case

00801741095344

1


Quantity

1/cs.


Dimensions

Rectangle 4" x 6" (10 cm x 15 cm)

GTIN

GTIN - Case 00801741095344 1

Packaging

Quantity 1/cs.

Product Basic Specification

Dimensions Rectangle 4" x 6" (10 cm x 15 cm)
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
  • product-image

    Phasix™ Mesh, Round, 4.5 in (11 cm)

  • product-image

    Phasix™ Mesh, Round, 3 in (7.6 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 4 in x 6 in (10.2 cm x 15.2 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 6 in x 8 in (15.2 cm x 20.3 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 8 in x 10 in (20.3 cm x 25.4 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 10 in x 12 in (25.4 cm x 30.5 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 2.4 in x 6.3 in (6 cm x 16 cm)

  • product-image

    Phasix™ Mesh, Square, 3 in x 3 in (8 cm x 8 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 3 in x 6.3 in (8 cm x 16 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 3 in x 8 in (8 cm x 20 cm)

  • product-image

    Phasix™ Mesh, Square, 4 in x 4 in (10 cm x 10 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 4 in x 8 in (10 cm x 20 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 4 in x 10 in (10 cm x 25 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 6 in x 10 in (15 cm x 25 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 6 in x 12 in (15 cm x 30 cm)

  • product-image

    Phasix™ Mesh, Square, 8 in x 8 in (20 cm x 20 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 8 in x 12 in (20 cm x 30 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 8 in x 16 in (20 cm x 40 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 10 in x 16 in (25 cm x 40 cm)

  • product-image

    Phasix™ Mesh, Square, 12 in x 12 in (30 cm x 30 cm)

  • product-image

    Phasix™ Mesh, Rectangle, 12 in x 18 in (30 cm x 45 cm)

  • product-image

    Phasix™ Mesh, Square, 14 in x 14 in (35 cm x 35 cm)

  • product-image

    Phasix™ Mesh, Square, 16 in x 16 in (40 cm x 40 cm)

  • product-image

    Phasix™ Mesh, Square, 18 in x 18 in (45 cm x 45 cm)

  • product-image

    Phasix™ Mesh, Square, 19.5 in x 19.5 in (50 cm x 50 cm)

References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false