{"AlternateComparison":true,"RelatedProducts":true,"Specification":true,"FeatureBenefit":false}
3DMax™ Synthetic mesh 3DMax™ Light Mesh

3DMax™ Light Mesh, Large Left, 4.1 in x 6.2 in (10.3 cm x 15.7 cm)

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.800.556.6756
BDISurgery@bd.com
Onsite Visiting
Location Icon
100 Crossings BoulevardWarwick, Rhode Island 02886United States
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Monday to Friday 8:15 AM to 6:00 PM EST
Fax Icon
1.800.531.4124
Custserv.davol@bd.com
Shipping a Product Back
Location Icon
100 Crossings Boulevard, Warwick, Rhode Island 02886, United States
Overview

A lightweight 3D-shaped mesh for laparoscopic approaches such as TAPP, TEP and Robotic TAPP

This lighter-weight version of our popular 3DMax™ Mesh features a large pore knit. It is easy to deploy and provides excellent visibility. It is designed to conform to the inguinal anatomy and retains its shape following laparoscopic introduction, including a robotic approach.

true
Features and Benefits
Promotional Story
false
References

Indications.

The 3DMax™ Light Mesh is indicated for use in the reinforcement of soft tissue where weakness exists, in the repair of inguinal hernias.

Contraindications.

1. Do not use this mesh in infants, children, or pregnant women, whereby future growth may be compromised by use of such materials.

2. The use of this mesh has not been studied in pregnant or breastfeeding women.

3. Literature reports that there may be a possibility for adhesion formation when polypropylene is placed in direct contact with the bowel or viscera.

Warnings.

1. The use of any synthetic mesh or patch in a contaminated or infected wound can lead to fistula formation and/or extrusion of the mesh.

2. If an infection develops, treat the infection aggressively. Consideration should be given regarding the need to remove the mesh. An unresolved infection may require removal of the mesh.

3. If unused mesh has been in contact with instruments or supplies used on a patient or contaminated with body fluids, discard with care to prevent risk of transmission of viral infections.

4. To prevent recurrences when repairing hernias, the mesh should be sized with appropriate overlap for the size and location of the defect, taking into consideration any additional clinical factors applicable to the patient. Careful attention to mesh fixation placement and spacing will help prevent excessive tension or gap formation between the mesh and fascial tissue.

5. The mesh is supplied sterile. Inspect the packaging to be sure it is intact and undamaged prior to use.

6. This mesh had been designed for single use only. Reuse, reprocessing, resterilization, or repackaging may compromise the structural integrity and/or essential material and design characteristics that are critical to the overall performance of the mesh and may lead to mesh failure which may result in injury to the patient. Reuse, reprocessing, resterilization, or repackaging may also create a risk of contamination of the mesh and/or cause patient infection or cross infection, including, but not limited to, the transmission of infectious diseases from one patient to another. Contamination of the mesh may lead to injury, illness or death of the patient or end user.

7. To avoid injury, careful attention is required if fixating the mesh in the presence of nerves, vessels, or the spermatic cord. Fastener penetration into underlying tissue containing nerves or blood vessels may result in the need for medical/surgical intervention, cause serious injury or permanent impairment to a body structure.

Precautions.

1. Please read all instructions prior to use.

2. Only physicians qualified in appropriate surgical techniques should use this mesh.

3. Do not cut or reshape the 3DMax™ Light Mesh as this may affect its effectiveness.

4. Use an appropriately sized trocar to allow mesh to slide down the trocar with minimal force.

5. If fixation is used, Bard® permanent or absorbable fixation devices or nonabsorbable monofilament sutures are recommended to properly secure the device. If other fixation devices are used, they must be indicated for use in hernia repair.

6. If fixation is used, care should be taken to ensure that the mesh is adequately fixated to the abdominal wall. If necessary, additional fasteners and/or sutures should be used.

Adverse Reactions.

Possible complications may include, but are not limited to, seroma, adhesions, hematomas, pain, infection, inflammation, extrusion, erosion, migration, fistula formation, allergic reaction and recurrence of the hernia or soft tissue defect. 

Please consult product package insert for more detailed safety information and instructions for use.

Please consult package insert for more detailed safety information and instructions for use.

BD-95700

true
Specification

GTIN - Case

00801741031038

1


Quantity

1/cs.


Dimensions

Left, Large 3DMax™ Light Mesh, 4.1" x 6.2" (10.3 cm x 15.7 cm)

GTIN

GTIN - Case 00801741031038 1

Packaging

Quantity 1/cs.

Product Basic Specification

Dimensions Left, Large 3DMax™ Light Mesh, 4.1" x 6.2" (10.3 cm x 15.7 cm)
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Alternatives Comparison
  • Alternatives Comparison

    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
  • Product Image
    • Product Name

      3DMax™ Light Mesh, Large Left, 4.1 in x 6.2 in (10.3 cm x 15.7 cm)
    • SKU Number

      0117311
    • Dimensions

      Left, Large 3DMax™ Light Mesh, 4.1" x 6.2" (10.3 cm x 15.7 cm)
    • Quantity

      1/cs.
  • Product Image
    • Product Name

      3DMax™ MID Anatomical Mesh, Large Left, 10 cm x 16 cm (4 in x 6 in)
    • SKU Number

      0116311
    • Dimensions

      NA
    • Quantity

      NA
Related Products
  • product-image

    3DMax™ Light Mesh, Medium Left, 3.1 in x 5.3 in (7.9 cm x 13.4 cm)

  • product-image

    3DMax™ Light Mesh, X-Large Left, 4.8 in x 6.7 in (12.2 cm x 17.0 cm)

  • product-image

    3DMax™ Light Mesh, Medium Right, 3.1 in x 5.3 in (7.9 cm x 13.4 cm)

  • product-image

    3DMax™ Light Mesh, Large Right, 4.1 in x 6.2 in (10.3 cm x 15.7 cm)

  • product-image

    3DMax™ Light Mesh, X-Large Right, 4.8 in x 6.7 in (12.2 cm x 17.0 cm)

  • product-image

    3DMax™ Mesh, Medium Left, 8.5 cm x 13.7 cm (3 in x 5 in)

  • product-image

    3DMax™ Mesh, Large Left, 10.8 cm x 16.0 cm (4 in x 6 in)

  • product-image

    3DMax™ Mesh, X-Large Left, 12.4 cm x 17.3 cm (5 in x 7 in)

  • product-image

    3DMax™ Mesh, Medium Right, 8.5 cm x 13.7 cm (3 in x 5 in)

  • product-image

    3DMax™ Mesh, Large Right, 10.8 cm x 16.0 cm (4 in x 6 in)

  • product-image

    3DMax™ Mesh, X-Large Right, 12.4 cm x 17.3 cm (5 in x 7 in)

References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false