DuoGlide Short-Term Dialysis Catheter

duoglide_hero1.jpg
Loading
Overview
  • Dual lumen
  • Kink-resistant catheter design
  • Symmetrical tip
  • Catheter length options
  • Maximal barrier trays
  • Straight or curved extension legs
true
Features and Benefits
Enhanced Acute Dialysis Care
  • The DuoGlide™ Short-Term Dual Lumen Dialysis Catheter is a kink resistant, dual-lumen catheter designed for flow rates of 400 mL/min1 with pressures of less than 250 mmHg1
  • At a flow rate of 300 mL/min the symmetrical tip design of the 24cm DuoGlide™ Short Term Dual Lumen Catheter demonstrated less than 1% recirculation on average when lines are run in forward and reverse2.

Optimal Performance Features2

  • Double Barrel Lumen Design: allows for flows of 400 mL/min1 in dialysis lumens with pressures of less than 250 mmHg1
  • Kink Resistant Catheter Design: resists kinking while providing stiffness for insertion
  • Symmetrical Tip: At a flow rate of 300 mL/min the symmetrical tip design of the 24cm DuoGlide® Short Term Dual Lumen Catheter demonstrated less than 1% recirculation on average when lines are run in forward and reverse.2 Note that recirculation in femoral catheters is likely significantly greater than in internal jugular placed catheters
  • Tip: is softer than shaft

 

Benefits of the DuoGlide™ Short-Term Dual Lumen Dialysis Catheters

  • 13 French DuoGlide™ Short-Term Dual Lumen Catheters are available in a variety of lengths including a long 30 cm length for femoral placements. Catheters are available in two configurations – with straight and curved extension legs – and in standard kits and full maximal barrier precautions trays. Full maximal barrier precautions trays help clinicians comply with CDC guidelines and feature a full body drape (70” x 110”), a surgical gown, and safety components.
  • FLEXIBILITY and UTILITY for You and Your patient
  • Indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis therapy via the jugular, subclavian and femoral vein
  • Catheter Length Options catheters are available in 12.5 cm, 15 cm, 20 cm, 24 cm, and 30 cm (lengths vary by catheter configuration)
Design
  • Flow Rate of 400 ml/min with pressures of less than 250 mmHg1 in dialysis lumens
  • Double Barrel Lumen Design with round intra lumens
Kink Characteristics
  • 13 Fr. Oval Catheter Shaft designed for excellent kink resistance
  • More Kink Resistant than competitive 11.5 Fr. dual lumen dialysis catheter2
Maximal Barrier Trays

Feature a full body drape (70" x 110"), surgical gown, and safety components.

Maximal barrier precautions help you comply with the latest guidelines from  the Centers for Disease Control (CDC).

Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
Resources

Kit Components

DescriptionTrayKit
DuoGlide® Short-Term Dual Lumen Dialysis Catheter11
Transparent Dressing11
Attachable Suture Wing11
Bouffant Cap10
ChloraPrep™ Solution One-Step Applicator20
End Cap22
Drape, Body, Fenestrated 70 in. x 110 in.10
StruXure™ Guidewire J-tip 70 cm x 0.89 mm (0.035 in.)11
Dualator® Vessel Dilator 11-13 Fr.11
Dualator® Vessel Dilator 12-14 Fr.11
Filter Straw20
Gloves10
Gown10
Introducer Needle, 18 Ga. x 7 cm (2.75 in.)01
Lidocaine HCI 1%, 5 ml Ampule10
Mask20
Needle Holder10
Safety Introducer Needle, 18 Ga. x 7 cm (2.75 in.)10
Safety Needle, 22 Ga. x 4 cm (1.5 in.)10
Safety Needle, 25 Ga. x 1.6 cm (0.625 in.)10
Safety Scalpel10
Sodium Chloride (Saline) 0.9% 10 ml Ampule20
Sponges, Gauze 10 cm x 10 cm (4 in. x 4 in.)60
Suture with Curved Needle10
Syringe, Luer Lock, 12 ml20
Syringe, Luer Slip, 6 ml20
Syringe, Luer Lock, 6 ml10

Frequently Asked Questions 

Catheter Indications and Materials

The DuoGlide Catheters are indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis therapy via the jugular, subclavian or femoral vein.

The catheter is intended for short-term vascular access only and is not to be used for any purpose other than indicated.

 

Catheter Performance

The DuoGlide Catheter flows at 400 mL/min for all lengths with low arterial/venous pressures (less than 250 mmHg). As suggested by in vitro data using a blood simulate approximating the viscosity of whole blood.

The rate of recirculation of the dialysis lumens is less than 1% on average in both the forward and reverse directions when tested in vitro1 at a flow rate of 300 mL/min with the symmetrical tip design of the 24 cm DuoGlide Short Term Dialysis Catheter. Note that recirculation in femoral catheters is likely significantly greater than in internal jugular placed catheters.2

Bench test results may not necessarily be indicative of clinical performance.

 

Catheter and Kit Options

The DuoGlide Catheter outer diameter is 13 French. The intra lumens are large 12 gauge lumens that allow for flows of 400 mL/min.

The DuoGlide Catheter is available in both straight and curved extension leg configurations.

The DuoGlide Catheter is available in 12.5 cm (curved extension configuration only), 15 cm, 20 cm, 24 cm, and 30 cm (straight extension configuration only).

Transparent, rotatable wing allows for easy visualization and cleaning of exit site.

 

Placement, Maintenance and Care

The DuoGlide Catheter is intended to be inserted in the jugular, femoral, or subclavian vein as required.

WARNING: The catheter must not be left in the femoral vein longer than three days.

The DuoGlide Dialysis Catheter is compatible with the following agents: Povidone iodine, 0.55% sodium hypochlorite solution, chlorhexidine gluconate 4%, chlorhexidine gluconate 2% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, bacitracin zinc ointments in petrolatum bases.

WARNING: Acetone and PEG-containing ointments can cause failure of this device and should not be used with polyurethane catheters. Chlorhexidine patches or bacitracin zinc ointments are the preferred alternatives.

Yes. The StatLock Catheter Stabilization Device is compatible and can be ordered separately from the Bard Medical Division at 800-526-4455. The part number is DI0122.

Yes, the DuoGlide Catheter may be exchanged over a guidewire. The wire included in the kit is a 0.035 inch wire which fits through the venous lumen of the catheter.

true
Reference
  1. As suggested by in vitro data using blood simulate approximately the viscosity of whole blood.
  2. Bench test R61545-0. Bench test results may not necessarily be indicative of clinical performance.

Available sizes: 13 Fr.

Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

BD-19967 (03/23)

true