Système de fixation absorbable ouvert OptiFix™

Faire progresser l’expérience de réparation des hernies ventrales ouvertes

OptiFix-Open
Chargement
Présentation
Optimized Design

For Open Ventral Hernia Repair


The OptiFix™ Open Absorbable Fixation System was designed for improved ease of use when fixating surgical meshes to the abdominal wall in open ventral hernia procedures by reducing limitations that exist with current laparoscopic straight devices. Combined with Ventrio™ ST, it provides a full system for open ventral hernia repair.

true
Caractéristiques et avantages
Fixation axée sur les résultats
Fixation axée sur les résultats
L’attache absorbable OptiFix™ Open en Poly(D, L-Lactide) est conçue pour offrir une performance optimale. Les caractéristiques de l’attache incluent, notamment : tête d’attache lisse qui minimise le risque de fixation des tissus1 Assure la fixation de la maille à la conception creuse Permet la pénétration des tissus dans l’attache1 Extrémité angulaire qui pénètre facilement dans la maille et les tissus1 Stabilisateurs qui améliorent la résistance à la rétention des tissus Empêche l’attache de ressortir
Fixation en toute confiance
Fixation en toute confiance
Les attaches OptiFix™ Open assurent une fixation sûre pendant la période de cicatrisation postopératoire, puis se résorbent lentement au fil du temps.
Sensation et conception ergonomiques préférées
Commentaires des chirurgiens4 Sur 16 chirurgiens interrogés après l’essai du dispositif OptiFix™ Open : 80 % ont favorisé la conception globale d’OptiFix™ Open par rapport à SecureStrap™ Open, tandis que plus de 87,5 % ont favorisé le dispositif par rapport à l’AbsorbaTack™ Short.
Référence

1. Preclinical data on file. Results may not correlate to clinical outcomes.

2. C. R. Bard Inc., bench data on file.

3 Preclinical data on file. Results may not correlate to clinical outcomes.

4 Survey of surgeons attending pre-clinical lab.

Results may not correlate to clinical outcomes. Data on file.

OptiFix™ Open Absorbable Fixation System

Indications

The OptiFix™ Open Absorbable Fixation System is indicated for the fixation of surgical mesh to tissues during open surgical procedures, such as hernia repair.

Contraindications

Contraindications associated with open surgical procedures relative to mesh fixation apply, including but not limited to:

  • Fixation of vascular or neural structures
  • Fixation of bone and cartilage,
  • Situations with insufficient ingrowth of tissue into the mesh over time, which could result in inadequate fixation once the fastener is absorbed.
  • Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as nerves, vessels, viscera or bone. Use of the OptiFix™ Open Absorbable Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 6.1 mm, the fastener head is another 0.6 mm (total 6.7 mm).

Warnings

The device may not fixate through prosthetics derived from biologic material such as xenografts and allografts. Prosthetic should be evaluated for compatibility prior to use. After use, the OptiFix™ Open Absorbable Fixation System may be a potential biohazard. Handle and dispose of in accordance with any local and federal laws regarding medical waste.

Adverse Reactions

Adverse reactions and potential complications associated with fixation devices such as the OptiFix™ Open Absorbable Fixation System may include, but are not limited to the following: hemorrhage; pain, edema and erythema at wound site; allergic reaction to Poly(D, L)-lactide; infection/septicemia; hernia recurrence/wound dehiscence.

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions and instructions for use.

true
BD-15157
Produits et accessoires
Références

1. Preclinical data on file. Results may not correlate to clinical outcomes.

2. C. R. Bard Inc., bench data on file.

3 Preclinical data on file. Results may not correlate to clinical outcomes.

4 Survey of surgeons attending pre-clinical lab.

Results may not correlate to clinical outcomes. Data on file.

OptiFix™ Open Absorbable Fixation System

Indications

The OptiFix™ Open Absorbable Fixation System is indicated for the fixation of surgical mesh to tissues during open surgical procedures, such as hernia repair.

Contraindications

Contraindications associated with open surgical procedures relative to mesh fixation apply, including but not limited to:

  • Fixation of vascular or neural structures
  • Fixation of bone and cartilage,
  • Situations with insufficient ingrowth of tissue into the mesh over time, which could result in inadequate fixation once the fastener is absorbed.
  • Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as nerves, vessels, viscera or bone. Use of the OptiFix™ Open Absorbable Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 6.1 mm, the fastener head is another 0.6 mm (total 6.7 mm).

Warnings

The device may not fixate through prosthetics derived from biologic material such as xenografts and allografts. Prosthetic should be evaluated for compatibility prior to use. After use, the OptiFix™ Open Absorbable Fixation System may be a potential biohazard. Handle and dispose of in accordance with any local and federal laws regarding medical waste.

Adverse Reactions

Adverse reactions and potential complications associated with fixation devices such as the OptiFix™ Open Absorbable Fixation System may include, but are not limited to the following: hemorrhage; pain, edema and erythema at wound site; allergic reaction to Poly(D, L)-lactide; infection/septicemia; hernia recurrence/wound dehiscence.

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions and instructions for use.

true
Ressources
Références

1. Preclinical data on file. Results may not correlate to clinical outcomes.

2. C. R. Bard Inc., bench data on file.

3 Preclinical data on file. Results may not correlate to clinical outcomes.

4 Survey of surgeons attending pre-clinical lab.

Results may not correlate to clinical outcomes. Data on file.

OptiFix™ Open Absorbable Fixation System

Indications

The OptiFix™ Open Absorbable Fixation System is indicated for the fixation of surgical mesh to tissues during open surgical procedures, such as hernia repair.

Contraindications

Contraindications associated with open surgical procedures relative to mesh fixation apply, including but not limited to:

  • Fixation of vascular or neural structures
  • Fixation of bone and cartilage,
  • Situations with insufficient ingrowth of tissue into the mesh over time, which could result in inadequate fixation once the fastener is absorbed.
  • Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as nerves, vessels, viscera or bone. Use of the OptiFix™ Open Absorbable Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 6.1 mm, the fastener head is another 0.6 mm (total 6.7 mm).

Warnings

The device may not fixate through prosthetics derived from biologic material such as xenografts and allografts. Prosthetic should be evaluated for compatibility prior to use. After use, the OptiFix™ Open Absorbable Fixation System may be a potential biohazard. Handle and dispose of in accordance with any local and federal laws regarding medical waste.

Adverse Reactions

Adverse reactions and potential complications associated with fixation devices such as the OptiFix™ Open Absorbable Fixation System may include, but are not limited to the following: hemorrhage; pain, edema and erythema at wound site; allergic reaction to Poly(D, L)-lactide; infection/septicemia; hernia recurrence/wound dehiscence.

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions and instructions for use.