{"AlternateComparison":true,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
Arista™ Synthetic mesh Arista™ Absorbable Hemostat

Arista™ AH FlexiTip™ Applicator, 14 cm (includes two applicators), 5 per Case

Includes two applicators

Overview
false
Features and Benefits
Promotional Story
false
References
false
Specification

GTIN - Pouch

10801741044066

2

GTIN - Case

20801741044063

10


Quantity

5/cs.

GTIN

GTIN - Pouch 10801741044066 2
GTIN - Case 20801741044063 10

Packaging

Quantity 5/cs.
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions

The Basics of Arista™ AH Absorbable Hemostatic Particles

  •  Topical hemostats include agents that act as a mechanical barrier to bleeding and provide a physical matrix for clotting, biologically active agents that catalyze coagulation, and combination therapies. 2
  • Hemostats can enhance clot formation and wound healing, and can be useful for controlling or preventing troublesome bleeding during surgical interventions where conventional methods of hemostasis are inadequate.2
  • AH is an absorbable powdered hemostatic agent intended for application to surgical wound sites to control bleeding. It is a fine, dry, sterilized white powder that is biocompatible, non-pyrogenic, and typically absorbed within 24-48 hours." 

 

  • Arista™ AH is a 100% plant based absorbable surgical hemostatic powder derived from purified plant starch. The power of Arista™ AH lies in its Microporous Polysaccharide Hemospheres, a patented blood clotting technology. Consisting of microporous particles with a controlled pore size, the spheres are designed to act as a molecular sieve. The powerful osmotic action dehydrates and gels the blood on contact to accelerate the natural clotting process." 

How Arista™ AH Works & Is Used

  • The acronym “RAPID” can be used to remember the application steps:
  • R (Remove): Remove all access blood
  • A (Apply): Apply AristaTM AH liberally to the bleeding site
  • P (Pressure): Administer wound-appropriate pressure until hemostasis is achieved
  • I (Irrigate): Irrigate and remove excess Arista™  AH from the site
  • D (Done): Hemostasis Hemostasis achieved— quickly, safely and effectively
 
  • With the FlexiTip™ spray applicator, applying Arista™ AH accurately and directly is fast and simple. The delivery system features a lightweight, plastic device with a long, flexible tube. The FlexiTip™  and FlexiTip™ XL extended reach applicator tips provide the precise and accurate delivery of Arista™ AH hemostatic powder from a simple, single-use device.1
  •  Arista Application: see instructions for use 1  
 
  • Directions for Use:
  1.  Blot, wipe, or suction the bleeding tissue. It is important to remove excess blood so Arista™ AH may be applied immediately and directly to the site of active bleeding.
  2. Position the applicator tip as close to the source of bleeding as possible. Immediately apply a liberal amount of Arista™ AH at the site of bleeding within the wound, to completely cover the wound. Deep wounds may require equally deep application of Arista™ AH. To minimize occlusion of the tip, pressure should be applied to deliver Arista™ AH as the applicator enters the wound
  3. Quickly apply wound-appropriate, direct pressure over the treated site. Use of a non-adhering substrate to apply pressure may prevent adhesion of  the  formed  clot to the surgical glove or other instrumentation. Amount and duration of pressure is wound dependent. For oozing, pressure may not be necessary. For more profusely bleeding wounds, pressure should be maintained longer.
  4. If bleeding or oozing continues, remove excess Arista™ AH and reapply.
  5.  If any material other than the clot-bound Arista™  AH  (i.e.  surgical dressing) adheres to the wound site, irrigate the material with saline and carefully remove it from the treated site.
  6.  Immediately upon contact with blood or fluid, Arista™ AH will swell to approximately 5 times its original volume. Once hemostasis is achieved, excess Arista™ AH should be carefully removed by irrigation and aspiration. Avoid irrigation of direct suction of the formed blood clot.1
  • Administration: A liberal amount of Arista™ AH should be applied to the bleeding site (see DIRECTIONS FOR USE) followed by pressure until hemostasis  is  achieved.  After hemostasis is achieved, Arista™  AH  should  be  removed  by  irrigation  and/or  aspiration.1

Examples of surgeries that Arista™ AH can be used in include:

  • Cardiothoracic and cardiovascular
  • Vascular
  • Gynecological
  • Urology
  • Orthopedic surgery
  • General surgery
  • Plastic surgery
  • Ear
  • nose
  • throat (ENT) surgery

Advantages of Arista™ AH

  • A wide variety of topical hemostats are approved as adjunctive therapies in the maintenance of hemostasis during surgical procedures in which conventional methods are insufficient or not practical.2
  •  Potential cost benefits in terms of preventing the further utilization of hospital resources to manage surgical bleeding. In addition to other patient blood management strategies, the intraoperative use of topical hemostats may reduce the need for transfusion of blood products (e.g., packed red blood cells, platelets, fresh frozen plasma) and reduce the duration of postoperative care (length of hospital stay) each of which is associated with substantial costs.2

Simple to Use

  •  Ready on demand
  • Simply pop the cap and apply the powder directly to the bleeding site
  • No mixing and no refrigeration
  • Five-year shelf life4

Safe and Thrombin-Free

  • Synthesized from a purified plant starch
  • Thrombin-free, biocompatible and nonpyrogenic
  • Typically absorbed and cleared within 24–48 hours by amylases
  • Arista™ AH is the only currently available hemostat that is approved for cell salvage compatibility1,6,7

Effective Hemostat

  • The clotting process begins on contact, regardless of patient’s coagulation status
  • Complete hemostasis can be achieved in minutes5
  • Provides broad area coverage

Arista™ AH Results and Case Studies

PMA clinical trial (General, Orthopedic, Cardiac)

Cardiac & Vascular:

ENT:

General:

Urology

References

 

  1. Arista™ AH IFU
  2. Gabay, M. & Boucher, B.A. An essential primer for understanding the role of topical hemostats, surgical sealants, and adhesives for maintaining hemostasis. Pharmacotherapy 33, 935-955 (2013).
  3. Safety and effectiveness of ARISTA™ AH have not been clinically evaluated in children and pregnant women. Because there have been reports of decreased amylase activity in newborns up to 10 months, absorption rates of ARISTA™ AH in this population may be longer than 48 hours
  4. Data on file
  5. ARISTA™ AH PMA Clinical Study P050038
  6. BD Data on file. Preclinical data may not correlate to clinical performance in humans.
  7. When Arista™ AH is used in conjunction with autologous blood salvage circuits, a 40 μ cardiotomy reservoir, cell washing, and 40 μ transfusion filter must be used.

BD-53859

true
References
false
Alternatives Comparison
  • Alternatives Comparison

    • Product Name
    • SKU Number
    • Quantity
    • Product Name
    • SKU Number
    • Quantity
    • Product Name
    • SKU Number
    • Quantity
    • Product Name
    • SKU Number
    • Quantity
  • Product Image
    • Product Name

      Arista™ AH FlexiTip™ Applicator, 14 cm (includes two applicators), 5 per Case
    • SKU Number

      am0004
    • Quantity

      5/cs.
  • Product Image
    • Product Name

      Arista™ AH FlexiTip™ XL Applicator, 38 cm, 5 per Case
    • SKU Number

      am0005
    • Quantity

      5/cs.
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false